                         GENERAL TERMS AND CONDITIONS
                                  (continued)

4.    QUALITY:

      4.1   General.  Shipper agrees that the Gas tendered for transport 
            hereunder shall meet the specifications set forth in this section. 
            Transporter may reject Gas tendered or delivered by Shipper that 
            fails to conform to the quality specifications provided in this 
            Tariff or which, in its reasonable judgment, may cause harm to its 
            facilities or diminish the quality of Gas in its system.  
            Transporter may under all circumstances subject, or permit the 
            subjection of, the Gas to compression, cooling, cleaning, products 
            extraction and other processes.

      4.2   Total Heating Value.  Gas delivered by Shipper hereunder shall 
            have a heating value of at least 975 Btu per cubic foot.  In the 
            event that the heating value of the Gas per cubic foot is below 
            975 Btu, Transporter has the option (a) to refuse to accept said 
            Gas so long as said heating value remains below 975 Btu per cubic 
            foot, or (b) to continue to accept delivery of said Gas.  The 
            maximum Btu content of Gas delivered by Shipper shall not exceed 
            1100 Btu per cubic foot.

      4.3   Objectionable Matter.  Shipper agrees that the Gas tendered for 
            transport hereunder:

            (a)   shall be commercially free from objectionable odors, dust, 
                  impurities, or other solid, gaseous or liquid matter 
                  (including, without limitation, any free water) which might 
                  interfere with its merchantability or cause injury to or 
                  interference with proper operation of the lines, regulators, 
                  meters or other appliances through which it flows;

            (b)   shall contain less than one fourth (1/4) grain of hydrogen 
                  sulfide per hundred cubic feet of Gas volume;

            (c)   shall not contain more than five (5) grains in total of 
                  sulphur compounds per hundred cubic feet of Gas volume;