Previous  Next  Search
Mississippi River Transmission Corporation
FERC Gas Tariff
Third Revised Volume No. 1

First Revised Sheet No. 87
Superseding
Original Sheet No. 87

                         GENERAL TERMS AND CONDITIONS
                                  (Continued)

4.    QUALITY

      4.1   General.  Customer agrees that the Gas tendered for transport 
hereunder shall meet the specifications set forth in this section.  MRT may 
reject Gas tendered or delivered by Customer that fails to conform to the 
quality specifications provided in this Tariff or which, in its reasonable 
judgment, may cause harm to its facilities or diminish the quality of Gas in 
its system.  MRT may under all circumstances subject, or permit the subjection 
of, the Gas to compression, cooling, cleaning, products extraction and other 
processes.

      4.2   Specifications.  Unless otherwise specified in the Service 
Agreement or Operational Balancing Agreement, or unless MRT waives the 
specification detailed herein if such waiver will not impair the integrity of 
MRT's system, the gas received or delivered under the terms of the Service 
Agreement or Operational Balancing Agreement shall conform to the following 
specifications:

            (a)   Solids.  The gas shall be commercially free from solid 
       matter, dust and gum forming constituents which might cause injury to 
       or interference with proper operation of the lines, storage wells, 
       meters, regulators or other appliances through which it flows.

            (b)   Oxygen.  The gas shall not at any time have an uncombined 
       oxygen content in excess of .05% by volume, and the parties shall make 
       every reasonable effort to keep the gas free from oxygen. 

            (c)   Carbon Dioxide.  The gas shall not at any time have a carbon 
       dioxide content in excess of two percent (2%) by volume. 

            (d)   Nitrogen.  The gas shall not at any time have a nitrogen 
       content in excess of two and one-half percent (2.5%) by volume. 

            (e)   Hydrogen.  The gas shall contain no carbon monoxide, 
       halogens, or unsaturated hydrocarbons, and no more than four hundred 
       parts per million (400 ppm) of hydrogen. 

            (f)   Liquids.  The gas shall be free of water and hydrocarbons in 
       liquid form at the temperature and pressure at which the gas is 
       delivered. 

             (g)  Water Vapor Content.  The gas shall in no event contain 
       water vapor in excess of seven (7) pounds per one million (1,000,000) 
       cubic feet, measured at a pressure base of 14.73 psia and at a 
       temperature of sixty degrees Fahrenheit. 

Issued by: Robert A. Trost, Vice President & General Manager
Issued on: February 1, 2005                   Effective on: August 3, 2005